- Volume: 400 liter
- Safe and reproducible incubation even under high batch throughputs in long-term operation
- Disinfection routine at 100 °C
- Stable atmosphere by inner glass door
- Temperature range: +5°C above ambient temperature to +100°C
- APT.line™ preheating chamber technology
- Adjustable fan speed
- Adjustable exhaust air flap
- Controller with timer functions
- Inner door made of tempered safety glass
- 2 chrome-plated racks
- Class 3.1 independent temperature safety device (DIN 12880) with visual
- temperature alarm
- Computer interface: RS 422
Description

Binder BF 400 Laboratory Incubator – Robust and Reliable Incubation with Forced Convection
The Binder BF 400 laboratory incubator from the Classic.Line series is engineered for dependable, high-capacity incubation where consistent heat distribution and precise control are essential. Featuring mechanical (forced) convection, it ensures fast heat-up times and excellent temperature uniformity—ideal for laboratories handling full loads and high-throughput workflows.
With a temperature range from +5 °C above ambient to 100 °C, the BF 400 supports a wide variety of incubation applications, from microbial cultivation to sample conditioning. APT.line™ preheating chamber technology ensures even temperature distribution across all interior levels, delivering reliable and reproducible results.
The BF 400 features practical design elements such as an adjustable fan speed, adjustable exhaust air flap, and controller with timer functions, giving users greater flexibility to adapt settings for specific protocols. Its inner door made of tempered safety glass allows safe observation without compromising internal conditions. A Class 3.1 safety system with a visual alarm (DIN 12880 compliant) ensures optimal operational safety, while an RS 422 interface supports external monitoring and data integration.
Key Features:
-
Temperature range: +5 °C above ambient to +100 °C
-
Mechanical (forced) convection for uniform temperature control
-
APT.line™ preheating chamber technology for thermal consistency
-
Adjustable fan speed for application-specific airflow control
-
Adjustable exhaust air flap for moisture and air exchange
-
Controller with timer functions for process flexibility
-
Tempered safety glass inner door for safe sample viewing
-
2 chrome-plated racks included
-
Class 3.1 temperature safety device with visual alarm (DIN 12880 compliant)
-
RS 422 computer interface for data integration and monitoring
Built for durability and ease of use, the Binder BF 400 laboratory incubator delivers reliable incubation performance and safety for laboratories in the BeNeLux region requiring flexibility, capacity, and consistent results.
Specifications
Warranty: 2 years
Lead time: 1-2 weeks
Designation | BF400-230V |
Article Number | 9010-0241 |
Performance Data Temperature | |
Temperature range | +5 °C above ambient temperature to 100 °C |
Temperature uniformity at 37°C | 0.4 ± K |
Temperature fluctuation at 37°C | 0.1 ± K |
Temperature fluctuation at 100°C | / |
Heating up time to 37°C | 12 min |
Heating up time to 100°C | / |
Recovery time after door was opened for 30 s at 37°C | 5 min |
Measures | |
Interior volume | 400 L |
Net weight of the unit (empty) | 145 kg |
Load per rack | 35 kg |
Permitted load | 90 kg |
Doors | |
Unit doors | 2 |
Internal Dimensions | |
Interior width | 1,000 mm |
Interior height | 800 mm |
Interior depth | 500 mm |
Wall clearance | |
Wall clearance back | 160 mm |
Wall clearance sidewise | 100 mm |
Housing dimensions not incl. fittings and connections | |
Width net | 1,235 mm |
Height net | 1,025 mm |
Depth net | 765 mm |
Electrical data | |
Housing protection acc. to EN 60529 | IP 20 |
Rated Voltage | 230 V |
Power frequency | 50/60 Hz |
Nominal power | 0,85 kW |
Nominal current | 3,7 A |
Unit fuse | 12,5 A |
Phase (Nominal voltage) | 1~ |
Environment-specific data | |
Sound-pressure level | / |
Energy consumption at 37°C | 56 Wh/h |
Energy consumption at 100°C | / |
Fixtures | |
Number of shelves (std./max.) | 2/9 |
- Access port with silicone plug: For introducing external measuring instruments. Large selection of different diameters and positions (left, right, or top)
- Interior socket: Waterproof, switched flush-mounting box (CA3GD) for nominal voltage in unit interior, with cover
and corresponding plug (nominal voltage; max. 500 W; max. 90 °C; protection class IP67) - Door lock: Lockable door handle prevents unauthorized access.
- Shelf racks: Perforated shelves or shelf racks, chrome-plated or made from stainless steel.
- Data Logger Kit T: Independent temperature data logging. The tailored product solution contains helpful accessories: From the magnetic mounting of the data logger to the BINDER unit and securing sensor cable for accurate readings.
- Services: You can access our installation, maintenance, calibration, validation, or warranty services by taking
out a Maintenance Service Agreement or by simply getting in touch when you need us.
More information is available in the accessories and services chapter. - BINDER INDIVIDUAL: Using a BINDER series production product as a basis, we develop individual solutions as a single unit or in small batches. All products are tested, certified, and supplied with a full functional guarantee and warranty. More information is available in the accessories and services chapter.