Erlab Captair 391 Smart Ductless Fume Hood
Pricing on request
The Erlab Captair 391 Smart is a compact 1-metre-wide ductless fume hood designed for laboratories needing high containment with minimal energy use.
Its oblong dual-hand opening sash reduces environmental turbulence and allows use of a single filtration column for lower operating costs.
Carbon and HEPA filtration ensure safe handling of vapours and powders.
Certified to NF X 15-211 and optimized for precision weighing.
Can be installed on an external bench or on an Erlab support stand.

Erlab Captair 391 Smart – 1-Metre Ductless Fume Hood for Powders, Weighing & Low-Energy Laboratories
The Erlab Captair 391 Smart extends Erlab’s compact ductless range with a practical 1,000 mm working width, offering more workspace than the 321 while preserving the same ultra-efficient single-column filtration architecture.
Its distinctive oblong front sash with two hand openings minimizes the impact of surrounding air movements on containment performance while improving ergonomics — and because only one filtration column is required, purchase cost and long-term operating expenses remain significantly lower than wider multi-column systems.
Instead of exhausting conditioned laboratory air outdoors like conventional ducted hoods, the Captair 391 Smart continuously draws contaminated air through a modular filtration column combining activated carbon for vapours and HEPA or ULPA filters for particulates, before safely returning purified air to the laboratory. This design dramatically reduces HVAC energy consumption and eliminates outdoor chemical emissions.
For powder handling, ductless filtration offers a critical advantage: particles are captured at source rather than settling inside extraction ducts. When equipped with particulate filters, the hood becomes ideal for APIs, toxic solids and pharmaceutical weighing tasks.
Because airflow is independent from building exhaust fluctuations, the hood delivers exceptional stability — enabling precision weighing down to semi-micro level (0.01 mg) without balance drift caused by pressure variations.
According to the datasheet, airflow is 220 m³/h, face velocity ranges from 0.4–0.6 m/s, and electrical consumption is only 65 W .
The unit complies with AFNOR NF X 15-211:2009, DIN 12 927, BS 7989 and EN 1822 HEPA/ULPA standards. Erlab’s Smart Technology provides continuous safety communication via light and sound signals, while monitoring airflow, temperature and humidity in real time.
Installation remains extremely flexible: the hood can be placed on an existing laboratory bench (Benchcap) or mounted on an Erlab mobile or fixed support stand (Mobicap), supporting future lab reconfiguration.
Each project includes Erlab’s ESP programme — covering risk analysis, certified installation and long-term protection monitoring — reinforcing Erlab’s position as the inventor and world leader in ductless fume hood technology .
Technical Specifications – Erlab Captair 391 Smart Ductless Fume Hood
| Specification | Value |
| Width (mm) | 1013 |
| Depth (mm) | 621 |
| Height (mm, min–max) | 1110–1285 |
| Air flow | 220 m³/h |
| Sash type | Oblong |
| Safety standards | AFNOR NF X15-211:2009 (FR) BS 7989 (UK) DIN 12 927 (DE) EN 1822:1998 (HEPA H14 & ULPA U17) EU Marking |
| Air face velocity | 0.4–0.6 m/s |
| Power consumption | 65 W |
| Voltage/Frequency | 110–230 V / 50–60 Hz |
| Structure | Electro-galvanized steel with antiacid polymer |
| Side and front panels | Chemical resistant acrylic |
| Filtration module | Polypropylene |
Features
| Feature | Specification |
| Communication Interface | Audible and light signals indicating: – Unit running time – Air face velocity – Filtration fault alarm – Fan failure alarm – Ventilation settings |
| Filtration Technology | 1 filtration column configurable for: – Liquids – Powders – Combined applications |
| Carbon Filtration (for gases & vapours) | Based on filtration column configuration (see filtration table) |
| Particulate Filtration (for powders) | Based on filtration column configuration (see filtration table) |
| Monitoring | Real-time control of safety settings |
| Environmental Monitoring | Temperature (T°) and Relative Humidity (RH) sensors |
| Internal Lighting | LED lighting > 650 lux |
| Anemometer | Air face velocity alarm |
| Anemometer | Air face velocity indicator |
| Chemical Listing | Compatible with 700+ chemicals compliant with AFNOR NF X15-211 |
| Ceiling Lighting | ON/OFF light button |
| Work Surfaces | – Tempered glass – Trespa® TopLabPLUS – 304L stainless steel |
Available Configurations for Erlab Captair 391 Smart
| Option | Description |
| Molecode | Type A (acids) Type F (formaldehyde) Type S (solvents) |
| Benches | Mobile (Mobicap) Fixed (Benchcap) |
| Bench Equipment (only for Trespa® TopLabPLUS fixed bench) | Technical gas outlets Water outlets Front control valves Sink Power sockets |
| Particulate Pre-filter | Protects main filter(s) from dust and large particles |
| Transparent Back Panel | Clear acrylic rear panel for enhanced visibility and supervision |
Alternative Ductless fume hoods

- Ductless fume cabinet
- Compliance: AFNOR NF X15-211: 2009
- Internal width: 1244 mm
- Energy consumption: 160 W
- Sash opening: reverso type
Price on request

- Ductless fume cabinet
- Compliance: AFNOR NF X15-211: 2009
- Internal width: 1244 mm
- Energy consumption: 65 W
- Sash opening: oblong type
Price on request

- Item code: H11074101
- Replacement AS type filter
- Scope: for organic vapors
- Models: all Erlab Captair Fume Hoods
- Replacement time: application dependent
Price on request

- Ductless fume cabinet
- Compliance: AFNOR NF X15-211: 2009
- Internal width: 969 mm
- Energy consumption: 105 W
- Sash opening: reverso type
Price on request

- Item code: H11074401
- Replacement F type filter
- Scope: Formaldehyde vapors
- Models: all Erlab Captair Fume Hoods
- Replacement time: application dependent
Price on request

- Ductless fume cabinet
- Compliance: AFNOR NF X15-211: 2009
- Internal width: 1769 mm
- Energy consumption: 160 W
- Sash opening: reverso type
Price on request