Erlab Captair 321 Smart Ductless Fume Hood
Pricing on request
The Erlab Captair 321 Smart is Erlab’s most compact ductless fume hood, only 800 mm wide and designed for laboratories needing high protection in limited space.
Its oblong sash with two hand openings minimizes environmental turbulence while enabling the use of a single filtration column for lower operating costs.
Carbon and HEPA filtration allow safe handling of vapours and powders.
Certified to NF X 15-211 and optimized for ultra-low energy consumption.
Can be installed on an external bench or on an Erlab support stand.

Erlab Captair 321 Smart – Ultra-Compact Ductless Fume Hood for Precision Work and Low Energy Use
The Erlab Captair 321 Smart is the most compact model in Erlab’s ductless fume hood range, featuring a slim 800 mm width footprint and a distinctive oblong front opening with two ergonomic hand ports.
This sash geometry reduces the influence of environmental air disturbances on the containment barrier while maintaining user protection — and because only one filtration column is required, it delivers a more accessible investment cost and lower long-term operating expenses than wider systems with multiple filter stacks.
Instead of exhausting conditioned laboratory air outdoors like traditional ducted hoods, the Captair 321 Smart continuously draws contaminated air through a modular filtration column combining activated carbon for vapours and HEPA or ULPA filters for particulates, before safely recirculating purified air back into the room. This drastically reduces HVAC energy demand and prevents emissions to the outside environment.
For powder handling and toxic solids, ductless filtration provides a major safety advantage: particles are captured directly at source rather than accumulating inside long extraction ducts. When fitted with particulate filters, the hood becomes a highly effective solution for pharmaceutical APIs and weighing workflows.
Because the hood is not connected to building exhaust systems, airflow remains extremely stable — enabling precision weighing down to semi-micro level (0.01 mg) without balance instability caused by pressure fluctuations in ducted installations.
The Captair 321 Smart complies with AFNOR NF X 15-211, EN 1822 and DIN 12 927 standards and operates with airflow around 220 m³/h while consuming only ~65 W, keeping lifetime energy costs exceptionally low.
Erlab’s integrated Smart Technology continuously communicates protection status through light and sound signals while monitoring airflow velocity, temperature and humidity.
Installation is flexible: the hood can be mounted on an existing laboratory bench or on a dedicated Erlab support stand, allowing easy integration into new builds, renovations or rental laboratories.
Each project is supported by Erlab’s ESP programme, which includes expert application risk assessment, certified commissioning and long-term safety monitoring — a key differentiator versus manufacturers that shift responsibility to the end user.
Technical Specifications – Erlab Captair 321 Smart Ductless Fume Hood
| Specification | Value |
| Width (mm) | 808 |
| Depth (mm) | 621 |
| Height (mm, min–max) | 1110–1285 |
| Air flow | 220 m³/h |
| Sash type | Oblong |
| Safety standards | AFNOR NF X15-211:2009 (FR) BS 7989 (UK) DIN 12 927 (DE) EN 1822:1998 (HEPA H14 & ULPA U17) EU Marking |
| Air face velocity | 0.4–0.6 m/s |
| Power consumption | 65 W |
| Voltage/Frequency | 110–230 V / 50–60 Hz |
| Structure | Electro-galvanized steel with antiacid polymer |
| Side and front panels | Chemical resistant acrylic |
| Filtration module | Polypropylene |
Features
| Feature | Specification |
| Communication Interface | Audible and light signals indicating: – Unit running time – Air face velocity – Filtration fault alarm – Fan failure alarm – Ventilation settings |
| Filtration Technology | 1 filtration column configurable for: – Liquids – Powders – Combined applications |
| Carbon Filtration (for gases & vapours) | Based on filtration column configuration (see filtration table) |
| Particulate Filtration (for powders) | Based on filtration column configuration (see filtration table) |
| Monitoring | Real-time control of safety settings |
| Environmental Monitoring | Temperature (T°) and Relative Humidity (RH) sensors |
| Internal Lighting | LED lighting > 650 lux |
| Anemometer* | Air face velocity alarm |
| Anemometer** | Air face velocity indicator |
| Chemical Listing | Compatible with 700+ chemicals compliant with AFNOR NF X15-211 |
| Ceiling Lighting | ON/OFF light button |
| Work Surfaces | – Tempered glass – Trespa® TopLabPLUS – 304L stainless stee |
Available Configurations for Erlab Captair 321 Smart
| Option | Description |
| Molecode | Type A (acids) Type F (formaldehyde) Type S (solvents) |
| Benches | Mobile (Mobicap) Fixed (Benchcap) |
| Bench Equipment (only for Trespa® TopLabPLUS fixed bench) | Technical gas outlets Water outlets Front control valves Sink Power sockets |
| Particulate Pre-filter | Protects main filter(s) from dust and large particles |
| Transparent Back Panel | Clear acrylic rear panel for enhanced visibility and supervision |
Alternative Ductless fume hoods

- Item code: H11074301
- Replacement K type filter
- Scope: Ammonia vapors
- Models: all Erlab Captair Fume Hoods
- Replacement time: application dependent
Price on request

- Ductless fume cabinet
- Compliance: AFNOR NF X15-211: 2009
- Internal width: 1769 mm
- Energy consumption: 160 W
- Sash opening: reverso type
Price on request

- Item code: H11074401
- Replacement F type filter
- Scope: Formaldehyde vapors
- Models: all Erlab Captair Fume Hoods
- Replacement time: application dependent
Price on request

- Item code: H11074101
- Replacement AS type filter
- Scope: for organic vapors
- Models: all Erlab Captair Fume Hoods
- Replacement time: application dependent
Price on request

- Item code: H11074061
- Replacement ULPA filter
- Scope: particles (filtration global efficiency =99,99995%)
- Models: all Erlab Captair Fume Hoods
- Replacement time: application dependent
Price on request

- Ductless fume cabinet
- Compliance: AFNOR NF X15-211: 2009
- Internal width: 1244 mm
- Energy consumption: 65 W
- Sash opening: oblong type
Price on request