The Erlab Captair 632B is an undercounter filtering chemical storage cabinet designed for safe storage of laboratory chemicals directly beneath workbenches.
Air is continuously extracted through activated carbon filters and recirculated to the room, eliminating the need for ducting.
Its ductless design prevents HVAC overcapacity, avoids environmental emissions and allows easy relocation.
Smart monitoring technology provides real-time safety alerts and filtration status.
Fully compliant with NF X 15-211 molecular filtration standards for daily laboratory protection

Erlab Captair 632B – Undercounter Filtering Chemical Storage Cabinet with Smart Monitoring

The Erlab Captair 632B is a ductless filtering chemical storage cabinet engineered specifically for installation under laboratory benches, offering flexible and energy-efficient storage of solvents, acids, formaldehyde, ammonia or powders directly inside the laboratory.

Instead of exhausting contaminated air outside the building, a built-in fan continuously draws air from the cabinet through activated carbon filters selected for the stored chemicals before returning purified air to the lab. This approach eliminates the need for compensating HVAC airflow, prevents increased energy consumption and avoids releasing pollutants into the external environment.

Because no ducting or building modifications are required, the Captair 632B is particularly suited for rental facilities, retrofit laboratories or sites that regularly reconfigure workspaces.

According to the datasheet, the cabinet features a single configurable filtration column that can be adapted for liquid chemicals, powders or combined storage. Carbon filtration types include AS (organic vapours), BE (acid vapours), F (formaldehyde) and K (ammonia), while optional HEPA H13 particulate filtration captures powders down to 0.1 µm with 99.95 % efficiency.

With an airflow of 11 m³/h and ultra-low power consumption of 20 W, the Captair 632B delivers continuous protection at minimal operating cost. Storage configurations allow up to 44 × 1 L bottles with sliding doors or tray systems, while the corrosion-resistant steel structure is coated with anti-acid polymer and fitted with transparent chemical-resistant acrylic doors for safe visibility.

Erlab’s filtration technology complies with the demanding AFNOR NF X 15-211:2009 standard, supported by the manufacturer’s ESP safety programme covering risk analysis, certified installation and long-term monitoring. Flex technology allows future reconfiguration when stored chemicals change, protecting your investment over time.

Technical specifications – Erlab Captair 632B Filtering Chemical Storage Cabinet

ParameterSpecification
Safety standardsFiltration performances tested according to the AFNOR NF X15-211:2009 standard: France EN 1822:1998 (HEPA H14 & ULPA U17 Filters) – EU Marking
Air flow11 m³/h
Voltage/Frequency110-230V / 50-60Hz
Power consumption20W
StructureCorrosion resistant electro-galvanized steel coated with antacid polymer
DoorsClear, chemical resistant acrylic for easy viewing
Filtration modulePolypropylene

Features

FeatureDescription
Communication interfaceWhen the light is pulsing:
Door(s) left open – Containment is compromised – Filter breakthrough
Filtration technology1 column that can be configured to handle liquids, powders, or both
Carbon filtrationAS: For organic vapours
BE: For acid vapours
F: For formaldehyde vapours
K: For ammonia vapours
Particulate filtration for powdersHEPA H13 Filter: 99.95% efficiency filtration of particles over 0.1μm in size (Optional)
MonitoringReal-time control of security settings (Not available on Captair 632B Midcap)
Monitoring of ambient storage conditionsTemperature (T°) / Hygrometry (RH) sensors (Not available on Captair 632B Midcap)
Doors sensorsAlarm if doors are left open (Not available on Captair 632B Midcap)

Storage Configurations

Option 1 – Sliding doorsOption 2 – Sliding shelf
Storage capacitiesAbout 44 × 1L bottlesTray: About 25 × 1L bottles
Shelf: About 35 × 100mL bottles or 70 × 50mL bottles
Storage compartments21
Delivered with2 trays + 2 sliding shelves1 tray + 1 sliding shelf
Absorbant mats42
LockKey lockKey lock

Options and technologies for Erlab Captair 632B filtering chemical storage cabinet

Detection sensors

  • Type A, for acids
  • Type F, for formaldehyde
  • Type S, for solvents

Filter configuration

  • Single carbon filter
  • Carbon + particle filter

Filters for first installation

  • H01015071 BF2 Hepa H13 for powder storage
  • H01012101 BF2 AS for predominantly solvent vapors
  • H01012201 BF2 BE for predominantly acidic vapors
  • H01012401 BF2 F for predominantly formaldehyde vapors
  • H01012301 BF2 K for predominantly ammonia vapors

Consumables

  • Z7PIDDI632B1 Absorbing mat for sliding doors and shelves Captair 632B Smart (batch of 10)
  • Z7PIDDI632B Absorbing mat for drawer Captair 632B Smart (batch of 10)
  • Z7PIDDI021 Absorbing mat for small sliding tray on Captair 632BSmart (batch of 10)

Alternative Storage cabinets

Scroll to Top

Request a quote for this product. Please provide your contact details below